Operating principle
GAP-SENSOR is generally called "an eddy currentdisplacement sensor". A high-frequency current issupplied to the coil inside the sensor head to generate ahigh-frequency electromagnetic field. When the target (a conductive or magnetic substance)approaches this electromagnetic field, an eddy currentis generated on the surface of the target and the sensorcoil impedance is changed. The sensor system detectsthe change in oscillation strength resulting from thisphenomenon to identify the relationship betweendisplacement and voltage.
 
 