For monitoring equipment in chemical plant
Vibration, displacement and rotation measurement under gas atmosphere
Domestic intrinsically-safe explosion proof(3aG5)certified product
Sensor | PU05GCEX | Cable length 400mm |
Sensor cable | PC10CEX | Cable length : 10m |
Joint | JPS-6 | Connector protective case |
Converter | 710510CEX | Connected extension cable 1m |
Safety barrier | MTL7796+ |
Linear amplifier | 71LCEX |
Power suply | 55SPS-3-01(+23.5V) | 3ch |
Output cable | OC-202BN-058 | Barrier of 2nd~Linear amplifier |
Between sensor and converter | Model | K71C□□G△△CEX | *According to specification sheet |
Safety barrier to linear amplifier(non hazardous area ) | Measuring range | 0.0~1.8mm |